Have a Question?
mmWave Radar sensing is unique, and getting acquainted with it and with D3 Embedded’s sensors can be tricky.
We’ve compiled some frequently asked questions and their answers below to help.
Yes, it comes flashed with the out of the box demo from Texas Instruments.
It is easy to get point cloud data out of the sensors and visualize it using our visualizer application. Following our Quick Start Guides, you can get up and running in a few minutes.
It can be tricky to optimize the configuration for a given use case, and we can offer paid services to optimize things for you.
Yes, they can.
For the RS-L6432x and RS-L1432x sensors, an example description can be found in the section titled “UART and Output to the Host” in the file <MMWAVE_L_SDK_INSTALL_DIR>/docs/api_guide_xwrL64xx/MOTION_AND_PRESENCE_DETECTION_DEMO.html. This is included with the L mmWave SDK from Texas Instruments: https://www.ti.com/tool/MMWAVE-L-SDK
For our RS-x843x sensors, see <MMWAVE_SDK_INSTALL_DIR>/packages/ti/demo/xwr68xx/mmw/docs/doxygen/html/index.html (for example). This is included with the mmWave SDK from Texas Instruments: https://www.ti.com/tool/MMWAVE-SDK
For our RS-294x sensors, see <MMWAVE_MCUPLUS_INSTALL_DIR>/<MMWAVE_MCUPLUS_INSTALL_DIR>/ti/demo/awr294x/mmw/docs/doxygen/html/index.html. This is included with the mmWave MCUPLUS SDK from Texas Instruments: https://www.ti.com/tool/MMWAVE-MCUPLUS-SDK
Yes, both UARTS are supported via a USB to UART bridge on the RS-x843AOPU and RS-x843 and via LV UART signals on RS-x843AOPC. Our RS-Lx432x sensors only support one UART via USB for both config and data. Most of our modules are delivered programmed with the Texas Instruments out of box demo.
You can change the chirp configuration easily. You create your own chirp configuration file, then load that from the visualizer when starting up. You will have to experiment and take care, however, because some chirp configurations can overheat the sensor, or will just not work. You can modify the chirp configuration and send it into the command line interface of the sensor.
Frame rate is commonly 10 Hz, but this is just a starting point. We have experience with frame rates from 100 Hz to multiple seconds.
Doppler speed can be measured up to the tens of m/s, however if objects with strong returns can be observed traveling with multiple samples, the speed can be calculated based on distance travelled and time. We have tracked objects up to 300 m/s this way.
Yes, our sensors support Texas Instruments SDK and Radar Toolbox development and programming. We can provide assistance with this with a support contract.
Yes, absolutely. The Texas Instruments chipset we use has a hardware accelerator for radar processing, a DSP for angle of arrival and other analysis, and an MCU which runs a clustering and tracking algorithm to provide a continuous track of object location and direction of travel. This can be demonstrated with the software we provide with a purchase. If you need a little help getting started beyond what we provide in the user guide, we can help via email (support@d3embedded.com).
Yes, our design supplies VOUT_PA with regulated 1.0 V to permit multiple TX.
Our 60 GHz radars can operate between 57 and 64 GHz. Our 77 GHz radars can operate 77 GHz to 81 GHz.
Please refer to the chirp tools from Texas Instruments:
https://dev.ti.com/gallery/view/mmwave/mmWaveSensingEstimator/ver/2.4.0
https://dev.ti.com/gallery/view/mmwave/mmWave_Demo_Visualizer/ver/3.6.0
This is described briefly in the Quick Start Guide that you will obtain with your purchase, and there is a readme file in the visualizer download.
You can certainly write your own Python script to capture and display data. We don’t provide source code for capturing data, but you can use our visualizer to do so. Texas Instruments also has example visualizers in their radar toolbox (https://www.ti.com/tool/download/RADAR-TOOLBOX) that will capture and display data. They also provide source code in Python.
U.S. and Canada grants are publicly recorded at the FCC and ISED respectively.
For FCC grants, visit https://apps.fcc.gov/oetcf/eas/reports/GenericSearch.cfm and search for Grantee Code 2ASVZ.
For Canada grants, visit https://sms-sgs.ic.gc.ca/equipmentSearch/searchRadioEquipments and search for Company Number 30644.
We have test reports for a limited number of sensors for CE compliance.
Absolutely. There is information on using Texas Instruments-based radar sensors with ROS here:
https://dev.ti.com/tirex/explore/node?node=A__AADmvwTa5NEerQpNX45UAg__radar_toolbox__1AslXXD__LATEST
ROS support is better for 60 GHz sensors like our RS-6843AOPU.
We have done a lot of work with ROS, and if you need assistance, let us know.
D3 Embedded offers off-the-shelf ruggedized radar modules, and we are also happy to customize your enclosure to fit your needs for a nominal fee.
If you intend to enclose the radar yourself, we recommend ABS, and have found that a flat radome works best for MIMO antennas.
For 77 GHz, we have found that an ABS radome with an air gap of 5.3 mm and a thickness of 2.3 mm provides the widest low-loss field of view.
For 60 GHz, we have found that an ABS radome with an air gap of 6.75 mm and a thickness of 2.9 mm is best.
We have detected trucks at over 130 m away with this sensor. We can also offer this information: https://www.ti.com/lit/an/swra593a/swra593a.pdf
Range is highly dependent on the target radar cross section, conditions, and clutter. The 70-80 meter range is for forward human detection. 300 meters and greater applies to much larger targets like trucks and ships.
This being said, we don’t necessarily guarantee ranges for our products since situations can be so different.
Each situation can be predicted using path loss equations, however it’s always best to do some empirical measurements.
For longer ranges, we have many antenna options beyond what we offer for sale on our store.
We would be happy to develop custom software for customers with a services engagement.
You are right. Range and doppler resolution are the strong suits of this technology. Angular resolution is not as good. There are two performance topics here. One is the ability of the radar to resolve two objects at the same range and same doppler speed from one another. This is “resolution” or “discrimination”. These radars are not as good at that due to the constrained aperture size, so these sorts of scenarios can require 15 or even 60-degree separation to resolve separate objects. Angular resolution for a single object can be quite good, however. This is dependent on the number of angle bins considered, which can be configured. Frequently the software is set up with 64 angle bins over the programmed field of view, but there can be more. A resource to understand range and angle resolution is found here: https://www.ti.com/lit/ab/swra841a/swra841a.pdf
We can recommend our RS-6843AOPU or RS-1843AOPU sensor for ranges up to 50 meters or more. The RS-6843 and RS-1843A (non-AOP) will have a higher range. We have other higher gain options for greater distances. Level probing radar for fill level is typically on 77 GHz, so the RS-1843AOPU and RS-1843A would match this application.
Please use Texas Instrument’s High Accuracy Level Sensing software available here:
https://dev.ti.com/tirex/explore/node?node=A__AL9rg5YoMYuWPFAZY0fC.Q__radar_toolbox__1AslXXD__LATEST
We recommend following the instructions in our Quick Start Guide prior to working with the Texas Instruments software.
The RS-1843AOPC can be used for level sensing, even though our FCC grant covers general usage. The field of view is around 120 degrees as shipped. This can be reduced with a customer supplied lens or RF absorbing baffle. The FOV can also be programmatically limited to a reduced range.
We can customize this product to include a lens, baffle, or modified chirp configuration to reduce FOV with a services engagement.
Our CAN sensors provide a hardware level CAN interface that does not have an upper-level personality like CANopen or J1939.
We can customize them to meet upper-level standards with some NRE funding.
These devices are FMCW only, however they can run multiple chirp profiles in different subframes repeating to get better resolution and longer range at the same time. They are also capable of phase modulating each transmitter to get MIMO operation even during simultaneous TX.
Our hardware does not support capturing raw ADC samples. We only support sending processed data (point cloud returns, heatmaps, etc.) via a USB or CAN port. Texas Instrument’s EVMs can work in conjunction with their DCA1000 to capture raw data.
The sensor price does not include design files. With a services engagement we would deliver design files developed as part of the project. We can also offer design files for a license fee.
You could remove the radar boards from the metal heatsink, but depending on the chirp configuration you could thermally overstress the unit if you do not monitor the temperature carefully. Our RS-Lx432x sensors are much lower power. We would suggest you look into using this sensor instead, if it meets your data processing needs. It puts out point cloud data just like the RS-6843AOPU, but at slightly reduced fidelity.